Release 10.1A: OpenEdge Data Management:
Database Administration
After-image Buffers (-aibufs)
Operating systemand syntax UNIXWindows-aibufsn Usewith Maximum value Minimum value Single-user default Multi-user default DBS – 1 – 20
nThe number of after-image buffers.
Use After-image buffer (-
aibufs) to specify the number of after-image buffers. This parameter is useful only when running the after-image writer (AIW) because the AIW writes the filled after-image buffers to disk, making the buffers available to other client and server processes. Try setting -aibufsto a value of 1.5 times the value of the Before-image Buffers (-bibufs) parameter, or a minimum of 5.Without the AIW writing the buffers, any gain from increasing the number of buffers is negligible.
|
Copyright © 2005 Progress Software Corporation www.progress.com Voice: (781) 280-4000 Fax: (781) 280-4095 |