After-image Buffers (-aibufs)

Operating system
and syntax
UNIX
Windows
-aibufs n
Use
with
Maximum value
Minimum value
Single-user default
Multi-user default
DBS
1
20

n

The number of after-image buffers.

Use After-image buffer (-aibufs) to specify the number of after-image buffers. This parameter is useful only when running the after-image writer (AIW) because the AIW writes the filled after-image buffers to disk, making the buffers available to other client and server processes. Try setting -aibufs to a value of 1.5 times the value of the Before-image Buffers (-bibufs) parameter, or a minimum of 5.

Without the AIW writing the buffers, any gain from increasing the number of buffers is negligible.